tvnovellas.info Readers SAE J518 PDF

SAE J518 PDF

Wednesday, June 19, 2019 admin Comments(0)

Nominal. to MPa Series1). Flange. (SAE Code 61). O-Rings3). Size. Clamping Screws. Flange Half and Bolt Pattern. D3. Screw Holes. Parker. Type I. MOUNTING. HARDWARE. O-RING. HHCS. 8SFX 8SFXO 5/X 12SFX 12SFXO SAE J_机械/仪表_工程科技_专业资料。SAE J HYDRAULIC FLANGED TUBE, PIPE,AND HOSE CONNECTIONS.


Author:JORGE LOVEBERRY
Language:English, Spanish, French
Country:Japan
Genre:Environment
Pages:131
Published (Last):29.09.2015
ISBN:698-9-58999-153-5
ePub File Size:27.33 MB
PDF File Size:19.26 MB
Distribution:Free* [*Sign up for free]
Downloads:37407
Uploaded by: MYRTIE

A. B. C. D. E. F. G. H. I. K. O-RING. HHCS. CODE 61 SPLIT FLANGE. 1/2”. F8SFO . 5/X SAE J flanges come in two pressure classes. The standard series, Code 61, which goes to 3, psi and the high pressure series, Code 62, where all the. This SAE standard covers complete general and dimensional specifications for the flanged heads and split flange clamp halves applicable to 4-bolt split flange type tube, pipe, and hose connections with appropriate references to the O-ring seals and attaching components used in.

Scope—This SAE Standard covers complete general and dimensional specifications for the flanged heads and split flange clamp halves applicable to four-bolt split flange type tube, pipe, and hose connections with appropriate references to the O-ring seals and attaching components used in their assembly. See Figures 1 and 2. Also included are recommended port dimensions and port design considerations. The flanged heads specified are incorporated into fittings having suitable means for attachment of tubes, pipes, or hoses to provide connection ends. These connections are intended for application in hydraulic systems, on industrial and commercial products, where it is desired to avoid the use of threaded connections.

Split flange clamp halves shall be as specified in Figure 4 and Table 1. Port dimensions and spacing shall be as specified in Figure 5 and Table 2.

Pdf sae j518

O-ring seals, having nominal dimensions as indicated in Table 1, are used in conjunction with these connections. Bolts for use with these connections shall be of the sizes and lengths indicated in Table 1.

Socket head cap screws of SAE Grade 5 material or better are acceptable. The following general specifications supplement the dimensional data contained in Table 1 with respect to all unspecified detail. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.

SAE J518 Split Flanges

SAE invites your written comments and suggestions. All rights reserved. Printed in U. The latest issue of SAE publications shall apply. Size Designation—Four-bolt split flange connection sizes are designated by the nominal flange size which corresponds to the maximum inside diameter of the hole through the flanged head.

Dimensions and Tolerances—Tabulated dimensions and tolerances shall apply to the finished parts, plated or otherwise processed, as specified by the purchaser. Material—Flanged heads shall be made of steel.

Pdf sae j518

Split flange clamp halves shall be made from a material with the properties in Table 3. Finish—The external surfaces and threads of all carbon steel parts shall be plated or coated with a suitable material that passes a 72 h salt spray test in accordance with ASTM B Any appearance of red rust during the 72 h salt spray test shall be considered failure, except for the following: a.

All internal fluid passages.

J518 pdf sae

Edges such as hex points, serrations, and crests of threads where there may be mechanical deformation of the plating or coating typical of mass-produced parts or shipping effects. Areas where there is mechanical deformation of the plating or coating caused by crimping, flaring, bending, and other post-plate metal forming operations.

Areas where the parts are suspended or affixed in the test chamber where condensate can accumulate. Any appearance of red rust during the 72 h salt spray test shall be considered failure, except for the following: a.

Pressure Ratings, General Reference

All internal fluid passages. Edges such as hex points, serrations, and crests of threads where there may be mechanical deformation of the plating or coating typical of mass-produced parts or shipping effects. Areas where there is mechanical deformation of the plating or coating caused by crimping, flaring, bending, and other post-plate metal forming operations.

Pdf sae j518

Areas where the parts are suspended or affixed in the test chamber where condensate can accumulate. NOTECadmium plating is not preferred due to environmental reasons.

SAE J Code 61 and Code 62 4-Bolt Flanges

Parts manufactured to this Standard after January 1, , shall not be cadmium plated. Internal fluid passages shall be protected from corrosion during storage. Changes in plating may affect assembly torques and require requalification, when applicable. Bolts shall be finished with a suitable coating that meet the previous requirements after a 16 h salt spray test in accordance with ASTM B